MSA XCell® Sensors

Gas: Carbon monoxide (hydrogen-resistant) Package: Two-tox Range: 0-1999 ppm CO Resolution: 1 ppm CO Response Time: t(90) <15 seconds normal temperature Alarm Setpoint: Min 10ppm/ Max 1700ppm Warranty: 3 years Advantages: • Performance: This XCell Sensor has 10 times less sensitivity to hydrogen (<5% Cross Sensitivity) • Long life: >4-year life means fewer sensor …

Get Price

Chat With WhatsApp

Sensors - 5

QEL Carbon Monoxide CO Sensor Parking Garage or Warehouse Q5-CO-250P-0-X $ 350. Buy It Now. $0 Shipping. Condition: New. ... Application- Honeywell DDC Space Sensor Dimensions(in. 5 1/32 in. high x 3 5…

Get Price

Chat With WhatsApp

CTS-M5 TOXIC GAS TRANSMITTER/SENSOR

TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE ... 0 ppm ppm ppm ppm ppm ppm CO 0 ppm 125 ppm 25 ppm 20 ppm 50 ppm 40 ppm NO 0 ppm 100 ppm 25 ppm 20 ppm 50 ppm 40 ppm NH 3 0 ppm 50 ppm 25 ppm 20 ppm 35 ppm 30 ppm O 2 0% 25% % Decreasing % % Increasing % . M-5 …

Get Price

Chat With WhatsApp

CO2 Sensors - HVAC-Talk

Apr 24, 2013· Hi, We have 50+ buildings and are looking at standardizing our brand and type of CO2 sensor. We currently have multiple brands/types (many of which need replacement or calibration). Moving forward, we would like to stick to one brand/type as this would make the replacement and/or calibration process a lot easier. In your opinion, what are the best CO2 sensors …

Get Price

Chat With WhatsApp

Gas & Specialty Sensors - Control Products

Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Duct Mount, 4-20mA or 2-10VDC Output or Modbus RTU Add to cart Details. Sale! 102151 – ACI – CO-R ... Controller, 32 dgital QEL sensors, eight 4-20mA inputs, 3 DPDT Relays, Steel Nema 1 Add to cart Details. Sale! 125946 – ACI – M …

Get Price

Chat With WhatsApp

CTS - M5 SERIES TOXIC GAS TRANSMITTER/SENSOR

CTS - M5 SERIES TOXIC GAS TRANSMITTER/SENSOR GAS SELECTION TABLE Gas Type (See Gas Selection Table for #) Revision (Factory Provided) Options (Enter 0 for No Selection) Relays (2 x SPDT & Buzzer) Conformal Coating C T S -M 5 X -Q 0 0 X R W 0 0 Gas Type # Max. Range Oxygen - O 2 130 0 to 25% v/v Nitrogen Dioxide - NO 2 Carbon Monoxide - CO

Get Price

Chat With WhatsApp

QEL Q5 Series Smart Gas Transmitters

RS-485 with QEL Controller Protocol Connects to Q4C Controller, M-Controller, and Q-Controller 4-20 mA, 2-10 VDC, 1-5 VDC Analog Signal Output Enclosure Rating: IP 66 & NEMA 4, 4X, 12 & 13 Operating Temperature:-40° C to 70° C, depends on sensor specification Ambient Humidity: 5…

Get Price

Chat With WhatsApp

Honeywell Fixed Gas Detection Calibration Handbook

Span Gas Value x Factor x = Calibration value (in VDC) (+/- 3 % of the scale) Full scale VA201T/M CALIBRATION INFORMATION - Q1 Sensor Gas (Q1) Sensor VA201T Scale VA201M Scale Warm-Up Factor Zero Pot Span Pot Flow Rate L/min Notes CL2 SCL2-7CLH SCL2-S7 ppm 15 ppm 5 min. - - 2 CO SCO-4BW 0 - 255 ppm 0 -250 ppm 5 min. - - 2